枫下家园 / 家用电器 / 求助:我家的furnace最近工作很不正常重新启动时,炉子会正常工作,但过2-3小时后,数字面板上显示HEAT ON,但机器没运转,机器上闪红灯,一短四长。过了几个小时,炉子又会自己启动,或则关掉,重启,炉子又正常工作,但过几小时,又停了,完全不按照我的设置工作。找了一位师傅来看,也没查出问题,哪位朋友有什么见解?谢谢!
-brain002(追风的小燕子);
2013-1-22
{270}
(#8014961@0)
-
你的炉子是什么型号的?
-bluesky2000(bluesky2000);
2013-1-23
(#8017008@0)
-
和我家的炉子一个毛病,楼主修好没有?
-ching_lu(清清);
2013-1-23
(#8017048@0)
-
还没有,昨天那个师傅说可能是温控器的问题,我想了想,我家是换了温控器之后出现这种情况。
-brain002(追风的小燕子);
2013-1-23
(#8017425@0)
-
Carrier model:58MSA
-brain002(追风的小燕子);
2013-1-23
(#8017429@0)
-
My furnace is Carrier too.
-freedom(深呼吸);
2013-1-24
(#8019603@0)
-
heat switch pressure fail. could be fan motor or heat exchange.
-justamom(just a mom);
2013-1-23
(#8017434@0)
-
多谢,请问怎么查才知道是哪一个呢?
-ching_lu(清清);
2013-1-24
(#8019546@0)
-
楼上不懂瞎说,两句话全没谱。就像:浑身上下脑袋痛,可能是LD吃多了。
-oxknife(天下无猪);
2013-1-25
(#8020673@0)
-
天下无猪请你不要随便judge别人。我有同样的经历,这是AtlasCare的tech说的。
-justamom(just a mom);
2013-1-31
(#8031939@0)
-
天下无猪还真没有冤枉你,也许你所说的TECH就是一个东郭先生。
-pingdan(pingdan);
2013-2-6
(#8042657@0)
-
麻烦请你推荐个tech. 谢谢先!
-justamom(just a mom);
2013-2-6
(#8042675@0)
-
你可以参看楼下推荐的Tech。
一般来说,控制暖炉的工作的一般有:温度控制器,HIGH LIMIT SWICH,废气风扇压力开关,还有火焰传感器,和火焰冒出传感器。所以像楼主家的情况,首先是看温度控制器工作是否正常,如果排除它的问题,鼓风机如果风速达不到设计风速或中间停转,热交换器将过热使HIGH LIMIT SWITCH 断开控制回路,停止暖炉的运行。当然如果这个SWITCH 有问题,也会中断暖炉的工作。所以楼主的问题,需要进行比较全面的检查和判断。可能需要很多时间。一般的TECH进行快速判断,如果花费时间太长,可能挣不到钱,有的干脆直接走人。
-pingdan(pingdan);
2013-2-7
{359}
(#8044789@0)
-
昨天我把温度一直固定在20度,不用那个program,炉子一整天都工作正常,今天我再试试看,也许真是温控器的问题。
-brain002(追风的小燕子);
2013-1-25
(#8020124@0)
-
换个温控器试试吧,我家上周日是温控器和吹风的马达都坏掉了,找了一个大家推荐的师傅换的。这么冷的天,赶紧修吧。
-cathy_ywf(春天-开心);
2013-1-25
(#8020209@0)
-
是呀,现在又不工作了,请告诉一个可靠的师傅,谢谢!前几天找的师傅,收了钱,事没办好,这2天打电话,都不接电话了,真是没有职业道德。
-brain002(追风的小燕子);
2013-1-25
(#8020963@0)
-
按照你的Furnace的牌子,到制造商网站上找本地的dealer来修。他们都是经过制造商的培训的
-isup(isup);
2013-1-29
(#8028390@0)
-
we have the same model and same symptom several years ago.Because we were in brand new house's first year so the furnace was still at warrantee. Builder sent a technician and fixed it. He just replace the big inside blower. He said he still have more than 10 blower in his car because lots of these type furnace had the same problem.
-zhouziren1(zhouziren);
2013-2-7
{276}
(#8044804@0)
-
新年快乐!请问是Blower 坏了,还是BLOWER 里的零件坏了?
-ching_lu(清清);
2013-2-8
(#8047214@0)
-
试一试清洁一下热传感器,取下来用砂纸稍稍打一下再装回去。
-li331(li331);
2013-1-29
(#8028372@0)
-
是高效炉吧?当初我家的那个也是这样的毛病,上网查,据说是普遍问题。切断电源十五分钟后再重启,成功的可能性大些。但最终还要换零件。我可以推荐个师傅,态度不错,价钱也合理。查 PM。
-rollor(Rollor 印刷店);
2013-1-29
(#8028407@0)
-
也请帮我推荐一下。非常感谢
-ching_lu(清清);
2013-2-5
(#8041696@0)
-
冷凝水下水会不会堵了?我家上次就是。。。冷凝水下水堵了,反溢回风扇/马达,导致不工作。等把水抽出来,或自然干掉后,又好了。
-shawn2001(crisis);
2013-2-21
{81}
(#8066152@0)
-
检查过滤网!
-luckyben(ben);