This topic has been archived. It cannot be replied.
-
枫下家园 / 美丽家居 / 家里和furnace相连的Electronic Air Cleaner不工作了(指示灯不亮),问了换新的报价700多,请问哪里可以找到会修理的师傅?先谢!
-2you2be(2y2m);
2010-2-24
(#5903304@0)
-
i think if the electronic air cleaner is not that old, you can try to fix it, but the price for the parts are not cheaper. otherwise take all stuff in the EAC out and put in a regular filter is ok.
-bluesky2000(bluesky2000);
2010-2-24
(#5903550@0)
-
曾经请过师傅来修,检查后说是part都好,就是指示灯不亮,他也搞不懂怎么回事。大家有没有水平高的师傅可以推荐?也想过把4”厚的电子过滤网拿出来换上普通的过滤网然后做个木头的空架子填上多余的空间,不知道木架子会不会有火患?
-2you2be(2y2m);
2010-2-24
(#5903696@0)
-
coule you tell me the brand and model number. you can get this information from the backside of the front cover.
-bluesky2000(bluesky2000);
2010-2-24
(#5903712@0)
-
It's Honeywell F50E 6074. Thanks for your time!
-2you2be(2y2m);
2010-2-24
(#5904088@0)
-
you can check follow the steps: 1. turn off the power for the EAC. 2. take out the cells out, leave the pre filter in. 3. push back the access door. 4. turn on the power. 5. make the furnace running and check the light is on or not.
-bluesky2000(bluesky2000);
2010-2-24
(#5904116@0)
-
I follow your instruction but the light is still off. Do you think if there's something wrong with light itself? Can I call you?
-2you2be(2y2m);
2010-2-24
(#5904261@0)
-
ok. now there are two things left to check. 1. power. check volts by multimeter. if no, fix wire. if power is ok 2. by pass air flow switch. light on, replace air flow switch. if no, replace power supply package.
-bluesky2000(bluesky2000);
2010-2-24
(#5904366@0)
-
pm you.
-bluesky2000(bluesky2000);
2010-2-24
(#5904370@0)